CORDS
Power cord without grounding
IDENTIFICATION CODE: OC2 ;A15 ;E05
IN COMPLIANCE WITH: SR CEI 60884:2003
Use
- For the supply of household electric appliances
- The cords are executed in compliance with the European Directives: 2001/95/EC concerning the general security of products (GPSD), 2011/65 RoHS
Materials
- Flexible cable for E01: HO3VVH2-F 2x0.50 mm2, 2x0.75 mm2; 2x1.00 mm2; for A15 / OC2 HO5VV-F 2x1.0 mm2; 2x1.5 mm2 of 1.5; 2; 2.5; 3; 5; 7; 10 m executed according to: SR EN 50525-2-11: 2011; DIN EN 50525-2-11 (VDE0285-525-2-11): 2012-01; EN 50525-2-11: 2011
- Non-removable injection sheet: for E05 with a core of: U = 250 V, I = 2.5A ac, 2N type: Taller GmbH: B01.001 1.6 SW, Standards: CEE7-Std.Sheet XVI, DIN 49464; for: OC2, A15 with core of: U = 250 V, I = 10 / 16A as, 2N type: Taller GmbH: B05.001, Standards: CEE7- Std.Sheet XVII IEC / EN60884,
- Colors: According to the order
Data sheet
- Rated voltage: 250 V c.a.
- Nominal load: 10/16 A for OC2; A15, 10A for E01
- Protection class: IP40 for A15, E01; IP 44 for OC2
- Length of: 1,5;2;2,5;3;5;7;10 m
WARNING
- Over passing the maximum accepted power can lead to the melting of the cable and can provoke fires
Product
Documents
Declaration of conformity
Report of test fire
-